Our Colocation and Data Center Services Are State-of-the Art Systems to Meet Changing Demand

We understand that what you need from data center services can change rapidly as your business changes. We have designed our data centers to keep up with this demand and to be constantly available to widely distributed users. Your application could grow from niche to mainstream in a matter of weeks, taxing even the most scalable architectures. Your industry may also require increasingly stringent privacy and compliance regulations. ATI has built its state-of-the-art data center with these requirements in mind. Our DC-area data center offer the following:

  • Reliability
  • Redundancy
  • Failover
  • Load balance
  • Business continuity
  • Uptime and extreme availability

ATI provides data center services and colocation from our two locations, known as DC-1 (Chantilly). Our data center and colocation facility provide power, cooling, and physical security racks and the ability to have cage space if necessary.

Chantilly VA Colocation Data Center and Services

Data Center Services Near Washington DCLocated in Chantilly, Virginia, with 3,000 square feet of raised floor, DC-1 is carrier neutral with a 2N configuration for power and cooling. All critical systems are monitored 24 hours a day, seven days a week, 365 days a year. This location offers the following features.

Power

  • Underground networked dedicated utility feed with a 2 megawatt dedicated transformer
  • Redundant Diesel generators
  • Redundant UPS systems
  • Redundant Power Distribution Units (PDUs)
  • Redudnat Battery Cabinets

Cooling

  • Redundant 120 ton Chillers
  • Redundant CRAH systems in each DC (we currently have two separate spaces)
  • Hot aisles containment for high-density accommodation

Fire protection

  • Multi-zone configuration
  • Smoke/heat detection system
  • Subfloor detection and floor fire protection

Security

  • 24/7 x 365 security surveillance monitoring
  • CCTV with 365-day retention
  • Multi-factor access control with biometrics, PIN, and card readers

Connectivity

  • Lit facility with multiple tier-1 carriers

Rockville MD Data Center

Located in Rockville, Maryland, with 6,000 square feet of raised floor, this facility is carrier neutral with N+1 configuration for power and cooling. All critical systems are monitored around the clock all year. Specs of this location are as follows.

Power

  • Underground networked dedicated utility feed
  • Redundant diesel generators
  • Redundant UPS system
  • Redundant Power Distribution Units (PDUs)

Cooling

  • Multi-stack chiller plant
  • Redundant cooling units with built-in CRAHs
  • Hot aisles containment for high density accommodation

Fire protection

  • Multi zone configuration
  • Smoke/heat detection system
  • Sub floor detection and floor fire protection

Security

  • 24/7 x 365 security
  • CCTV with 90 days retention
  • Card access control

Connectivity

  • Lit facility with multiple tier-1 carriers

 

Contact Us Today For Data Center Colocation Services for Virginia and Washington D.C. Businesses

No matter what your data center or colocation requirements are, we are confident we can meet and even exceed your expectations. Contact us by calling (855) 658-8600 to get more information about how our data centers can serve the needs of your small to medium-sized business.